Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit

Model NO.: YSX500G
Small Focus: 1.0mm;: Big Focus: 2.0mm
Focus Distance: 100cm
Bed Surface: 2000mm*750m*690mm
Tube Current: Radiography32mA~630mA/16mA-200mA
Output Voltage: Radiography 40-125kv Step 1kv
Intermittent Mode: 100kv, 500mA, 50kw/100kv, 200mA, 20kw
Cassette Size: 5× 7 8× 10 10× 12 11× 14
Output Power: 50kw/20kw
Exposure Time: Radiography 3ms~6s Adjustable
Focus: 150khu/140khu
Trademark: YSENMED
Transport Package: Wooden Box
Specification: ISO certificate
Origin: China
HS Code: 9022199090
China medical manufacturer radiography whole body
x-ray unit YSX500G

Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit

Product Configuration: 

No

Part Name

Qty

1

X-ray tube

1

2

Radiographic Table

1

3

Collimator

1

4

Microcomputer console

1

5

High-voltage generator,

1

6

High voltage cable

2

7

Vertical bucky stand

1

 

Standard Accessories:

No

Part Name

Qty

1

Lateral cassete holder with clamp

1

2

Bucky wall stand handgrip

1

3

Compression belt

1

4

Lead screen

1

5

Lead apron

2

6

Cassettes (8" x 10, 10" x 12", 12" x 15", 14" x 14")

4

7

Intensifying screen (8" x 10, 10" x 12", 12" x 15", 14" x 14")

4

 

Technical parameters of main components:

CONTENTS

YSX200G

YSX500G

Intermittent mode

100kV ,200mA,20kW

100kV ,500mA,50kW

Power Voltage

380V±10% 50Hz±10%

tube current

Radiography   16mA~200mA

Radiography32mA~630mA

Output Voltage

Radiography 40-125KV  step 1kV;

resistance power

less than  0.5Ω

Output power

20kW

50kw

Exposure Time

Radiography 0.0025s~6.4s adjustable

Radiography  3ms~6s   adjustable

Nominal Frequency

30kHz

Speed of anode rotating

2800r/min

Anode heat capacity

140KHU

150KHU

Focus

Small focus:1.0mm  Big focus:2.0mm

Length*width*height of bed surface

2000mm×750mm×690mmDeviation:±10mm

Horizontal movement distance of table

≥200mm

Vertical movement distance of table

≥900mm

Distance from table surface to film

50mm±2mm

Distance of vertical movement

770mm±10mm;

800mm-1100mm

Moving crosswise (left & right)

+180°~-180°deviation<±2°

Moving lengthways (along ground railway)

≥1300mm

600mm

Fixed beam filtration grid density

≥40 lines/cm.

grid ratio

10:01

Focus Distance

100cm

Cassette size

5″×7″ 8″×10″ 10″×12″ 11″×14″ 14″×17″

 


Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit


Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit




Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit

Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit

Ysx500g China Medical Manufacturer Radiography Whole Body X-ray Unit
 
 
 

Massage Pillow & Cushion

Massage Pillow & Cushion,Cushion ,Pillow,Pillow Case

fdhdfjh , http://www.nbmassager.com