20: 1 Reduction Dental Implant Motor Surgical Contra Angle Handpiece

Model NO.: RH-20P6
Application: Adult, Child
Loading Way: Gland Type
Head Diameter: Middle Head
Exhaust Way: Internal Exhaust
Number of Holes: No Holes
Connection: Without Quick Connector
Rotating Speed: Reduction Contra Angle
Product Name: 20:1 Dental Implant Handpiece
Ratio: 20:1 Push Button Contra Angle
Rotation Speed: 5~2000rpm
Sterilization: up to 135 Degree
Applicable Bur: 2.345-2.355mm
Torque: 55 N.Cm
Dental Filed: Dental Clinic , Dental Hospital , Dentists
Fitting with E Type Motor: Swiss, Japan, Korea Famous Brand Implant
Quality: Dental Handpiece NSK
Noise: Less Than 70dB
Trademark: novo
Specification: 1PC/Box
Origin: China
HS Code: 90184990
20:1 Reduction Dental Implant Motor Surgical Contra Angle handpiece 

Specification:

Push button type 
torque force: ≤55 N.cm 
Gear Ratio: 20:1 Reduction
Max speed: 2000RPM
Ergonomics coating, more hygeian.
Sterilization: up to 135 ºC
Applicable bur: Φ2.345-2.355mm
Fitting with E type motor, can be available to match up with Swiss, Japan, Korea  famous brand implant system.
 

Dental handpieces right use way:
1. The need to use a clean , dry , oil-free air compressors for medical use ;
2. The air pressure between 2.3-2.8kgf / cm2;
3. Place the adapter with quick connector at the bottom of a combination of dental handpieces , and confirm that the card lock fixed ;
4. Press the pedal , handpiece operation and examine whether the normal operation of the spray head . If everything is normal, you can start using the handpiece.

After each patient use , maintenance should be done as follows
1. First remove the diamond burs , and clean up all the teeth on dental handpieces precipitate ;
2. Use a metal needle to clean the spray holes and fumaroles ;
Note: The spray holes and diamond burs into 40 -degree angle , fumaroles and diamond burs to a 30 degree angle.
3. Place the clean lubricating oil is sprayed into the axial hole 1-2 seconds ( diamond burs is plugged holes ) ;
4. In the bottom of the handpiece were ( with / without quick connector ) two kinds of styling , make the right amount of lubricant is injected into the bottom ;
5. The handpiece with quick connector combination ( first determine the water switch is turned off )
6. Replace the diamond burs , surrounded by white silk cloth handpiece head ( make sure the needle does not touch the diamond burs and white gauze , so as not to tie ) ;
7. pedal depressed for about 20 seconds , look at whether there is in white gauze on any stain. If there are stains on the white gauze , again, add oil , starting from item 4 continued routine maintenance , know that white gauze until no stain ;
8. Finally, no more than 135 degrees Celsius temperature and high pressure sterilization. 

20: 1 Reduction Dental Implant Motor Surgical Contra Angle Handpiece
20: 1 Reduction Dental Implant Motor Surgical Contra Angle Handpiece
20: 1 Reduction Dental Implant Motor Surgical Contra Angle Handpiece
20: 1 Reduction Dental Implant Motor Surgical Contra Angle Handpiece
 

Others NBR Coated Gloves

Work Glove,Safety Glove,Nitrile Glove

Fenghua Jade Motor Co., Ltd. , http://www.xwgloves.com