Constant temperature and humidity test chamber maintenance

Constant temperature and humidity test chamber maintenance and maintenance Constant temperature and humidity test machine is a test chamber that combines high temperature, low temperature and damp heat - high and low temperature wet heat alternating test chamber, which is more difficult to repair than other environmental test equipment. . Let's take the high-low temperature wet heat alternating test chamber as an example. Let's talk about the structure of constant temperature and humidity test and some common faults and troubleshooting methods. I. Structure of constant temperature and humidity test chamber The constant temperature and humidity test chamber consists of a tank, a wind circulation system, a refrigeration system, a heating system and a humidity control system. The air circulation system generally adopts a structure that can adjust the direction of air supply; the humidification system adopts two types of boiler humidification and surface evaporation; the cooling and dehumidification system adopts an air conditioning working condition refrigeration structure; the heating system adopts electric heating fin heating and electric furnace direct heating. Structure; temperature and humidity test method adopts dry and wet ball test method, and also uses humidity sensor direct measurement method; control and display operation interface adopts temperature and humidity separation independent and temperature and humidity combination controller.

In the damp heat test, the actual humidity will reach 100% or the actual humidity will be very different from the target humidity. The value is much lower. The former phenomenon may be caused by the drying of the gauze on the wet bulb sensor. Then check the wet bulb sensor. Whether there is water shortage in the water tank, the water level in the water tank is automatically controlled by a water level controller. Check whether the water supply system of the water level controller is normal and the water level controller works normally. Another possibility is that the wet gauze is hardened due to the long use time or the purity of the water supply, so that the gauze becomes hard and the gauze can not absorb moisture and is dry. The above phenomenon can be eliminated by replacing or cleaning the gauze. The latter phenomenon is mainly because the humidification system does not work. Check the water supply system of the humidification system, whether there is a certain amount of water in the water supply system, whether the water level control of the humidification boiler water level is normal, and whether the water level in the humidification boiler is normal. If everything above is normal, then check the electrical control system, which should be repaired by professional maintenance personnel.

When the equipment suddenly fails during the test operation, the corresponding fault display prompt appears on the control meter and there is an audible alarm prompt. The operator can quickly check which type of fault is involved in the troubleshooting chapter of the operation of the equipment, and then ask the professional to quickly eliminate the fault to ensure the normal operation of the test. Other environmental testing equipment will have other phenomena in use, and it will be specific phenomena, specific analysis and elimination. The high and low temperature test chamber or the constant temperature and humidity test chamber should be regularly maintained, the condenser of the refrigeration system should be cleaned regularly, the moving parts should be lubricated according to the instructions, the electrical control system should be regularly maintained and checked, etc. These tasks are essential. .

Shrimp Series

Shrimp Series,Wild Shrimp,Frozen Pink Shrimp,Frozen Vannamei Shrimp

Zhejiang Zhoushan Jiaze Aquatic Co., Ltd. , https://www.tianjia-aquatics.com