6 good habits to raise the life of the vibrating screen by 2 times

As the saying goes, "details determine success or failure." The purpose of using various vibrating screens to improve product purity and precision is actually the process of dying with details. Therefore, the role of vibrating screens in this intensive economic society with “details to see the truth” is not important.
However, the sharp weapon of the gods also needs maintenance. The so-called "grinding the knife does not mistake the woodworker", and the following six good habits have not only greatly slowed down the speed of machine replacement, but also avoided the frequent replacement of equipment. The economic burden is more able to keep the precision and efficiency of the equipment in the “premium” period while it is running.
First, the first use of the vibrating screen must carefully read the instructions attached, understand the precautions and maintenance instructions of the vibrating screen,
Second, before the vibrating screen work, carefully check the screen, seals, vibration motor status, shock absorbing spring, various bolts are installed and tightened, the fuel consumption and lubrication of the vibration motor is good, and in the course of use, 8 hours The cycle checks the components of the vibrating screen and the discharge conditions.
Third, strictly follow the uniform feeding, especially the staged accumulation of a large amount of materials on the drying net.
It can be said that a vibrating screen has a large output force, and the loss of Zui is a screen mesh. Except for special customization, the common screens on the market are made of stainless steel metal woven mesh, because of its moderate cost and universal material availability. Strong. However, due to the characteristics of stainless steel, if large-volume materials are often stacked in the stage on the screen, the screen will be deformed or even damaged under the violent gravity impact, which will cause the precision output to be affected. It is self-evident that the importance of uniform feeding.
If the amount is too large to grasp the amount of feed, Jinjiashun recommends that you consider adding a bag.
Fourth, the equipment needs to be cleaned before parking for a single job.
After a single day of work, the equipment must be idling for a few minutes, and at the same time use high-pressure water guns to clean up the residue of the screen surface. Because of the different materials, the screen that has been contaminated with the remaining materials for a long time will be corroded to varying degrees. Affect the strength and life of the screen.
5. When it comes to the type of production line, it must be recorded and handed over.
Vibrating screens are often used in the company's assembly line operations, and may require vibrating screens for 24 hours without stopping. At this time, Jinjiashun Company recommends that the duty personnel need to record the working time, processing volume, screen components, problems and solutions of the vibrating screen. Method and so on. This allows the replacement to better understand the state of the vibrating screen and to specifically inspect, record and maintain the vibrating screen.
6. Regular maintenance and maintenance of vibration motors
The vibration motor can be said to be the source of power for a vibrating screen. It is also the defender of the vibrating screen. The quality of the vibrating motor is usually not cheap. It can be replaced by a few times and can almost match the price of a new vibrating screen. It is. Therefore, Jinjiashun Company recommends that the maintenance of the vibration motor be necessary both economically and in terms of work efficiency.
The maintenance of the vibration motor is also very simple. It is only necessary to periodically inject lubricant into the motor or replace the lubricant. If the working time is long and the processing volume is large, the injection and oil change work should be more frequent, so as to ensure the good power output of the vibration motor.
The above six points can significantly optimize the life and screening efficiency of your vibrating screen. Jinjiashun Company recommends that you do the above 6 points, which not only can greatly reduce unnecessary expenses, but also improve the life of the vibrating screen. At least 1 time, why not?

ELISA Analyzer

Processing high-throughput samples, intelligent reuse for large-capacity publishing, work surface: 200cm, 8 sample injection needles, 12 temperature-controlled incubation positions, 12 room temperature incubation positions, 32 plate storage positions, Sunrise microplate reader, HydroFlex plate washer, up to 512 specimens, sequential loading of samples, reagents, microplates Parallel loading of up to 6 plates for fast dispensing.

The automatic enzyme immunoassay analyzer is based on the principle that the enzyme and the substrate can produce a color reaction, the absorption lines of different substances have different characteristics, and strictly abide by the Lambert-Beer law, quantitative and qualitative analysis of substances. instrument. The method of analyzing the content of various enzymes such as antigen or antibody generally mainly adopts colorimetric method. In practice, spectrophotometry is the basic working principle of an automatic enzyme immunoassay analyzer. The light emitted by the light source lamp becomes a beam of monochromatic light after passing through a filter or a monochromator. The monochromatic light beam passes through the sample to be tested in the microtiter plate, and part of the monochromatic light beam is absorbed by the sample and reaches the photodetector. The intensity of the light signal projected on it is converted into the magnitude of the electrical signal by the photodetector. This electrical signal is processed by pre-amplification, logarithmic amplification, analog-to-digital conversion, etc., and then sent to the microprocessor for data processing and calculation, and the test results are output by the display and printer. The microprocessor completes the movement in the X and Y directions of the mechanical drive through the control circuit.
The automatic enzyme immunoassay analyzer adds the sample to the microwells of the pre-coated antigen or antibody microtiter plate, washes after the reaction, removes the unseparated ligand, then adds the enzyme isolate, after incubation, washes again , remove the unseparated compound, and then add the enzyme substrate, after the reaction, the colored final product is formed, and the stop solution is added to stop the reaction. The absorbance of each microwell of the microtiter plate is read by the wavelength that has been set by the spectrophotometer. The concentration value of the analyte in the sample is calculated by the absorbance value of the sample and the standard curve, so that the quantitative result can be obtained, or the absorbance of the sample is compared with that of the standard product, so that the positive or negative qualitative result can be obtained.

ELISA analyzer,enzyme immunoassay workstation,automatic enzyme immunoassay analyzer,automatic enzyme immunoassay system

Jilin Sinoscience Technology Co. LTD , https://www.jilinsinoscience.com